Product Description

  • Maximum PV open circuit voltage  – 150V absolute maximum coldest conditions 145V start-up and operating maximum
  • Maximum efficiency 98%
  • Self-consumption 10 mA
  • Charge voltage ‘absorption’ Default setting: 14,4 / 28,8 / 43,2 / 57,6V (adjustable)
  • Charge voltage ‘float’ Default setting: 13,8 / 27,6 / 41,4 / 55,2V (adjustable)
  • Charge algorithm – multi-stage adaptive
  • Temperature compensation -16 mV / °C resp. -32 mV / °C
  • Protection – Battery reverse polarity (fuse, not user accessible) PV reverse polarity / Output short circuit / Over temperature
  • Operating temperature -30 to +60°C (full rated output up to 40°C)
  • Humidity 95%, non-condensing
  • Data communication port and remote on-off VE.Direct
  • Parallel operation  – Yes (not synchronized)